Products
Permanent Magnet Synchronous Motor (PMSM) for Compressors & Industrial Air Handling
High Efficiency & Energy Savings Superior Power Density Precision Performance Low Maintenance & Long Life Smart Control Compatibility Environmental Benefits
Classification:
Working Principle of Permanent Magnet Synchronous Motor (PMSM)
Jasung Permanent Magnet Synchronous Motor (PMSM)
High Efficiency & Energy Savings
Eliminated Slip Losses
◇ No slip-induced losses (zero rotor iron/copper losses at fundamental frequency)
Permanent Magnet Excitation Advantages
◇ Unity power factor (up to 1.0) capability
◇ Reduced reactive power consumption
◇ Lower stator current → 15-25% decreased copper losses vs. induction motors
Optimized Magnetic Circuit Design
◇ Higher pole arc coefficient than induction motors
◇ Reduced average flux density → 30% lower core losses at rated voltage
Advanced Loss Mitigation
◇ Trade-off in stray losses:
◇ Increased by PM field harmonics
◇ Decreased via enlarged air gap design
◇ Net 10-15% lower total losses than premium IE4 induction motors
| Product | Product Category | Voltage | Power Range | Product Application |
| Permanent Magnet Synchronous Motor 600-3000RPM |
Explosion-proof | 380/415V/460V | 11KW-315KW,355KW-710KW | Oil & gas extraction (drilling rigs, oil pumps, compressors) Refineries (reactor agitators, centrifugal pumps) Chemical plants (flammable liquid transfer, gas compression) Underground ventilation fans, conveyor belt drives Coal dust transport equipment, drainage pumps Alcohol extraction workshops, spray drying towers Flour/sugar powder conveying systems, edible oil pressing equipment |
| 660V | 11KW-315KW,355KW-710KW | |||
| 1140V | 11KW-315KW,355KW-1600KW | |||
| 3300V/4610V | 200KW-1600KW | |||
| 6000V | 200KW-1600KW | |||
| 10000V | 200KW-1600KW | |||
| Non-explosion proof | 380/415V/460V | 11KW-315KW,355KW-710KW | For textile/engineering vehicles/belt machine tightening/ air cooling island/flotation machine/separator/mixer/grinding machine/ball mill etc |
|
| 660V | 11KW-315KW,355KW-710KW | |||
| 1140V | 11KW-315KW,355KW-3000KW | |||
| 3300V/4610V | 200KW-3000KW | |||
| 6000V | 200KW-3000KW | |||
| 10000V | 200KW-3000KW |
Technical Specifications

Other voltages customizable, up to 10KV
| Frame | Pole | Installation dimensions | Outline size | |||||||||||
| A | B | 0 | D | E | F | G | H | K | AB | AD | HD | L | ||
| 355 | 4~10 | 630 | 800 | 224 | 110 | 210 | 28 | 100 | 355 | 35 | 760 | 760 | 1130 | 1950 |
| 400 | 4-10 | 710 | 900 | 224 | 120 | 210 | 32 | 109 | 400 | 35 | 840 | 900 | 1260 | 2180 |
| 450 | 4~10 | 800 | 1000 | 250 | 130 | 210 | 32 | 119 | 450 | 42 | 990 | 940 | 1380 | 2250 |
| Model | Rated Power (kW) |
Rated Voltge A |
Rated Current A |
Syncvonous apeed (r/min) |
Raled Torque (N.m) |
Rated Emcency (%) |
Rated Power Fador |
Pull in torque mulipler |
Pul-out torque mutpler |
Locked-rotor torgue mutpller |
Locked-rotor current multipher |
| JXSS-355-4-355-380 | 355 | 380 | 580.4 | 1500 | 2259.9 | 96.8 | 0.96 | 12 | 1.6 | 17 | 9.5 |
| JKSS-400-4-355-380 | 400 | 380 | 654 | 1500 | 2546.4 | 96.8 | 0.96 | 1.2 | 1.6 | 17 | 9.5 |
| JKSS-450-4-355-380 | 450 | 380 | 735.8 | 1500 | 2854.7 | 96.8 | 0.96 | 12 | 1.6 | 17 | 9.5 |
| JKSS-500-4-400-380 | 500 | 380 | 817.5 | 1500 | 3183.0 | 96.8 | 0.96 | 1.2 | 1.6 | 1.7 | 9.5 |
| JXSS-560-4-400-380 | 560 | 660 | 527.2 | 1500 | 3565.0 | 96.8 | 0.96 | 1.2 | 1.6 | 1.7 | 9.5 |
| JXSS-630-4-400-380 | 630 | 660 | 593.1 | 1500 | 4010.6 | 968 | 0.96 | 12 | 1.6 | 1.7 | 9.5 |
| JXSS-710-4-450-380 | 710 | 660 | 668.4 | 1500 | 4519.9 | 968 | 0.96 | 12 | 1.6 | 1.7 | 9.5 |
| JXSS-800-4-450-380 | 800 | 660 | 753.1 | 1500 | 5092.8 | 968 | 0.96 | 12 | 1.6 | 1.7 | 9.5 |
| JXSS-900-4-450-380 | 900 | 660 | 847.2 | 1500 | 5729.4 | 968 | 0.96 | 1.2 | 1.6 | 1.7 | 9.5 |
| JXSS-280-6-355-380 | 280 | 380 | 459.7 | 1000 | 2673.7 | 96.4 | 0.96 | 1.2 | 1.6 | 19 | 9.5 |
| JXSS-315-6-355-380 | 315 | 380 | 517.2 | 1000 | 3007.9 | 96.4 | 0.96 | 1.2 | 1.6 | 19 | 95 |
| JXSS-355-6-355-380 | 355 | 380 | 582.8 | 1000 | 3389.9 | 96.4 | 0.96 | 12 | 1.6 | 19 | 9.5 |
| JXSS-400-6-400-380 | 400 | 380 | 656.7 | 1000 | 3819.6 | 96.4 | 0.96 | 12 | 1.6 | 19 | 9.5 |
| JXSS-450-6-400-380 | 450 | 380 | 738.8 | 1000 | 4297.1 | 96.4 | 0.96 | 12 | 1.6 | 19 | 9.5 |
| JXSS-500-6-400-380 | 500 | 380 | 820.9 | 1000 | 4774.5 | 96.4 | 0.96 | 12 | 1.6 | 1.9 | 9.5 |
| JXSS-560-6-450-380 | 560 | 660 | 529.4 | 1000 | 5347.4 | 96.4 | 0.96 | 1.2 | 1.6 | 1.9 | 9.5 |
| JX5S-630-6-450-380 | 630 | 660 | 595.5 | 1000 | 6015.9 | 96.4 | 0.96 | 1.2 | 1.6 | 19 | 9.5 |
| JXSS-710-6-450-380 | 710 | 660 | 671.1 | 1000 | 6779.8 | 96.4 | 0.96 | 1.2 | 1.6 | 19 | 9.5 |
| JXS5-220-8-355-380 | 220 | 380 | 363.5 | 750 | 2801.0 | 95.8 | 0.96 | 12 | 1.6 | 1.8 | 9.5 |
| JXSS-250-8-355-380 | 250 | 380 | 413 | 750 | 3183.0 | 95.8 | 0.96 | 12 | 1.6 | 1.8 | 9.5 |
| JXSS-280-8-355-380 | 280 | 380 | 462.6 | 750 | 3565.0 | 95.8 | 0.96 | 12 | 1.6 | 18 | 9.5 |
| JXSS-315-8-400-380 | 315 | 380 | 520.4 | 750 | 4010.6 | 95.8 | 0.96 | 12 | 1.6 | 18 | 9.5 |
Advantages of Permanent Magnet Synchronous Motor (PMSM)
High Efficiency & Energy Savings
◇ Achieves IE4/IE5 efficiency levels (up to 98%) due to zero rotor losses
◇ 15-30% lower energy consumption compared to induction motors
◇ Maintains high efficiency even at partial loads
Superior Power Density
◇ Compact size with 20-40% higher torque-to-weight ratio
◇ Enables direct-drive applications by eliminating gearboxes
Precision Performance
◇ Excellent speed stability (±0.1% speed regulation)
◇ Fast dynamic response with vector control capability
◇ Smooth torque production with minimal cogging
Low Maintenance & Long Life
◇ No brushes/slip rings (brushless design)
◇ Reduced wear with fewer moving parts
◇ Permanent magnets retain properties for decades
Smart Control Compatibility
◇ Seamless integration with modern drives and IoT systems
◇ Enables predictive maintenance through embedded sensors
◇ Adaptable to Industry 4.0 automation networks
Environmental Benefits
◇ No rare earth material waste during operation
◇ Lower operating temperatures reduce cooling needs
Typical Applications
| ✔ Industrial Ventilation (Mining, Cement, Steel Plants) ✔ HVAC Systems (Large Commercial Buildings, Data Centers) ✔ Power Plant Cooling Fans ✔ Wastewater Treatment Aeration Blowers ✔ Marine & Offshore Ventilation |
![]() |
FAQ
Q: How to protect PMSMs during inverter failure?
Answer:Safety designs:
◇ Mechanical eddy current brake (emergency stop)
◇ Redundant rotor short-circuit device (active demagnetization)
◇ System-level overspeed protection circuit (auto power cutoff)
Q: Why do oil & gas industries prefer PMSM explosion-proof motors?
Answer:Industry fit:
◇ 8-12% higher efficiency than Ex e induction motors (saves >$50k/year in electricity)
◇ No sparking design (ATEX/IECEx Zone 1 compliant)
◇ Optional gas detection sensors (trip function integration)
Q: How to implement energy regeneration in PMSMs?
Answer:Regenerative braking:
◇ Basic: Braking unit + resistor on DC bus (low-cost)
◇ Advanced: Bi-directional converter for grid feedback (>90% recovery efficiency)
Q: How do pole numbers affect PMSM performance?
Answer:Design trade-offs:
◇ High-pole motors (e.g., 16-pole): High torque at low speed, but limited max RPM
◇ Low-pole motors (e.g., 4-pole): High-speed capable, but may need gearbox
◇ Optimal: Fractional-slot windings (reduces cogging torque)
Q: What new materials could replace NdFeB in the future?
Answer:Emerging technologies:
◇ Iron-nitrogen magnets (Fe16N2): Theoretical 130MGOe energy product
◇ Nanocomposite magnets (SmCo/FeCo hybrid)
◇ Hot-pressed NdFeB (higher coercivity, 250°C rated)
Keyword:
High Efficiency & Energy Savings
Superior Power Density
Precision Performance
Low Maintenance & Long Life
Environmental Benefits
High-Performance Pmsm
Next Page
Find Your Products
Keywords:Permanent Magnet Direct Drive Pulley | Permanent Magnet Synchronous Motor | Permanent Magnet Direct Drive Motor
Related Products
Online Message
Please leave your email, our professional person will contact you asap!