JASUNG

Products


+
  • 1(1749716617948).png
  • 2(1749716617949).jpg

Permanent Magnet Synchronous Motor (PMSM) for Compressors & Industrial Air Handling​

High Efficiency & Energy Savings​​ ​​Superior Power Density​​ ​​Precision Performance​​ ​​Low Maintenance & Long Life​​ ​​Smart Control Compatibility​​ ​​Environmental Benefits​​

Working Principle of Permanent Magnet Synchronous Motor (PMSM)

Jasung Permanent Magnet Synchronous Motor (PMSM) 

High Efficiency & Energy Savings​​

Eliminated Slip Losses​​

◇ No slip-induced losses (zero rotor iron/copper losses at fundamental frequency)

Permanent Magnet Excitation Advantages​​

◇ Unity power factor (up to 1.0) capability

◇ Reduced reactive power consumption

◇ Lower stator current → 15-25% decreased copper losses vs. induction motors

Optimized Magnetic Circuit Design​​

◇ Higher pole arc coefficient than induction motors

◇ Reduced average flux density → 30% lower core losses at rated voltage

Advanced Loss Mitigation​​

◇ Trade-off in stray losses:

◇ Increased by PM field harmonics

◇ Decreased via enlarged air gap design

◇ Net 10-15% lower total losses than premium IE4 induction motors

 

Product Product Category Voltage Power Range Product Application
Permanent Magnet Synchronous Motor
600-3000RPM
Explosion-proof  380/415V/460V 11KW-315KW,355KW-710KW Oil & gas extraction (drilling rigs, oil pumps, compressors)
Refineries (reactor agitators, centrifugal pumps)
Chemical plants (flammable liquid transfer, gas compression)
Underground ventilation fans, conveyor belt drives
Coal dust transport equipment, drainage pumps
Alcohol extraction workshops, spray drying towers
Flour/sugar powder conveying systems, edible oil pressing
equipment
660V 11KW-315KW,355KW-710KW
1140V 11KW-315KW,355KW-1600KW
3300V/4610V 200KW-1600KW
6000V 200KW-1600KW
10000V 200KW-1600KW
Non-explosion proof 380/415V/460V 11KW-315KW,355KW-710KW For textile/engineering vehicles/belt machine tightening/
air cooling island/flotation machine/separator/mixer/grinding machine/ball mill etc
660V 11KW-315KW,355KW-710KW
1140V 11KW-315KW,355KW-3000KW
3300V/4610V 200KW-3000KW
6000V 200KW-3000KW
10000V 200KW-3000KW

 

Technical Specifications

 

Other voltages customizable, up to 10KV 

Frame Pole Installation dimensions Outline size
A B 0 D E F G H K AB AD HD L
355 4~10 630 800 224 110 210 28 100 355 35 760 760 1130 1950
400 4-10 710 900 224 120 210 32 109 400 35 840 900 1260 2180
450 4~10 800 1000 250 130 210 32 119 450 42 990 940 1380 2250

 

Model Rated Power
(kW)
Rated Voltge
A
Rated Current
A
Syncvonous apeed
(r/min)
Raled Torque
(N.m)
Rated Emcency
(%)
Rated Power
Fador
Pull in torque
mulipler
Pul-out torque
mutpler
Locked-rotor
torgue mutpller
Locked-rotor
current multipher
JXSS-355-4-355-380 355 380 580.4 1500 2259.9 96.8 0.96 12 1.6 17 9.5
JKSS-400-4-355-380 400 380 654 1500 2546.4 96.8 0.96 1.2 1.6 17 9.5
JKSS-450-4-355-380 450 380 735.8 1500 2854.7 96.8 0.96 12 1.6 17 9.5
JKSS-500-4-400-380 500 380 817.5 1500 3183.0 96.8 0.96 1.2 1.6 1.7 9.5
JXSS-560-4-400-380 560 660 527.2 1500 3565.0 96.8 0.96 1.2 1.6 1.7 9.5
JXSS-630-4-400-380 630 660 593.1 1500 4010.6 968 0.96 12 1.6 1.7 9.5
JXSS-710-4-450-380 710 660 668.4 1500 4519.9 968 0.96 12 1.6 1.7 9.5
JXSS-800-4-450-380 800 660 753.1 1500 5092.8 968 0.96 12 1.6 1.7 9.5
JXSS-900-4-450-380 900 660 847.2 1500 5729.4 968 0.96 1.2 1.6 1.7 9.5
JXSS-280-6-355-380 280 380 459.7 1000 2673.7 96.4 0.96 1.2 1.6 19 9.5
JXSS-315-6-355-380 315 380 517.2 1000 3007.9 96.4 0.96 1.2 1.6 19 95
JXSS-355-6-355-380 355 380 582.8 1000 3389.9 96.4 0.96 12 1.6 19 9.5
JXSS-400-6-400-380 400 380 656.7 1000 3819.6 96.4 0.96 12 1.6 19 9.5
JXSS-450-6-400-380 450 380 738.8 1000 4297.1 96.4 0.96 12 1.6 19 9.5
JXSS-500-6-400-380 500 380 820.9 1000 4774.5 96.4 0.96 12 1.6 1.9 9.5
JXSS-560-6-450-380 560 660 529.4 1000 5347.4 96.4 0.96 1.2 1.6 1.9 9.5
JX5S-630-6-450-380 630 660 595.5 1000 6015.9 96.4 0.96 1.2 1.6 19 9.5
JXSS-710-6-450-380 710 660 671.1 1000 6779.8 96.4 0.96 1.2 1.6 19 9.5
JXS5-220-8-355-380 220 380 363.5 750 2801.0 95.8 0.96 12 1.6 1.8 9.5
JXSS-250-8-355-380 250 380 413 750 3183.0 95.8 0.96 12 1.6 1.8 9.5
JXSS-280-8-355-380 280 380 462.6 750 3565.0 95.8 0.96 12 1.6 18 9.5
JXSS-315-8-400-380 315 380 520.4 750 4010.6 95.8 0.96 12 1.6 18 9.5

 

Advantages of Permanent Magnet Synchronous Motor (PMSM) 

High Efficiency & Energy Savings​​

◇ Achieves IE4/IE5 efficiency levels (up to 98%) due to zero rotor losses
◇ 15-30% lower energy consumption compared to induction motors
◇ Maintains high efficiency even at partial loads

​​Superior Power Density​​

◇ Compact size with 20-40% higher torque-to-weight ratio
◇ Enables direct-drive applications by eliminating gearboxes

​​Precision Performance​​

◇ Excellent speed stability (±0.1% speed regulation)
◇ Fast dynamic response with vector control capability
◇ Smooth torque production with minimal cogging

​​Low Maintenance & Long Life​​

◇ No brushes/slip rings (brushless design)
◇ Reduced wear with fewer moving parts
◇ Permanent magnets retain properties for decades

​​Smart Control Compatibility​​

◇ Seamless integration with modern drives and IoT systems
◇ Enables predictive maintenance through embedded sensors
◇ Adaptable to Industry 4.0 automation networks

​​Environmental Benefits​​

◇ No rare earth material waste during operation
◇ Lower operating temperatures reduce cooling needs

 

 Typical Applications​​

✔ ​​Industrial Ventilation​​ (Mining, Cement, Steel Plants)
✔ ​​HVAC Systems​​ (Large Commercial Buildings, Data Centers)
✔ ​​Power Plant Cooling Fans​​
✔ ​​Wastewater Treatment Aeration Blowers​​
✔ ​​Marine & Offshore Ventilation​ 

 

FAQ

Q: How to protect PMSMs during inverter failure?​​
Answer:Safety designs:​​
◇ Mechanical ​​eddy current brake​​ (emergency stop)
◇ Redundant ​​rotor short-circuit device​​ (active demagnetization)
◇ System-level ​​overspeed protection circuit​​ (auto power cutoff)
​Q:  Why do oil & gas industries prefer PMSM explosion-proof motors?​​
Answer:Industry fit:​​
◇ 8-12% higher efficiency than Ex e induction motors (saves >$50k/year in electricity)
◇ No sparking​​ design (ATEX/IECEx Zone 1 compliant)
◇ Optional ​​gas detection sensors​​ (trip function integration)
​Q: How to implement energy regeneration in PMSMs?​​
Answer:Regenerative braking:​​
◇ Basic: ​​Braking unit + resistor​​ on DC bus (low-cost)
◇ Advanced: ​​Bi-directional converter​​ for grid feedback (>90% recovery efficiency)
​​Q: How do pole numbers affect PMSM performance?​​
Answer:Design trade-offs:​​
◇ ​​High-pole motors​​ (e.g., 16-pole): High torque at low speed, but limited max RPM
◇ ​​Low-pole motors​​ (e.g., 4-pole): High-speed capable, but may need gearbox
◇ Optimal: ​​Fractional-slot windings​​ (reduces cogging torque)
​​Q: What new materials could replace NdFeB in the future?​​
Answer:​Emerging technologies:​​
◇ ​​Iron-nitrogen magnets​​ (Fe16N2): Theoretical 130MGOe energy product
◇ ​​Nanocomposite magnets​​ (SmCo/FeCo hybrid)
◇ Hot-pressed NdFeB​​ (higher coercivity, 250°C rated)

Keyword:

High Efficiency & Energy Savings​​

​​Superior Power Density​​

​​Precision Performance​​

​​Low Maintenance & Long Life​​

​​Environmental Benefits​​

High-Performance Pmsm

Find Your Products

All
  • All

Keywords:Permanent Magnet Direct Drive Pulley | Permanent Magnet Synchronous Motor | Permanent Magnet Direct Drive Motor

Online Message

Please leave your email, our professional person will contact you asap!